Confirm the installation method against the actual wall before approving office storage. HYB01-2420 is listed at 2400 × 400 × 2090 mm and HYB02-2412 at 2400 × 400 × 1200 mm. These dimensions do not establish whether wall restraint is required, what fixing suits the wall or which work the furniture quotation includes.
Catalogue examples and dimensions
| Catalogue range | Catalogue reference | Listed dimensions (mm) |
|---|---|---|
| Huanying | HYB01-2420 | 2400 × 400 × 2090 |
| Huanying | HYB02-2412 | 2400 × 400 × 1200 |
Provide usable information about the wall
Identify the wall construction and any lining, concealed services or restrictions relevant to the installation. Use project information confirmed by the responsible team, and label unknown conditions. A photograph of the finished surface does not identify every layer or prove fixing suitability.
Give the furniture supplier the exact selected cabinet, intended contents and installation position. Ask it to state its proposed support or restraint method for that arrangement. Keep a generic product illustration separate from the method actually accepted for the project.
Approve the method and its responsibilities
Have the relevant suppliers and project team review the proposed fixing method and any necessary preparation. Identify who supplies hardware, checks the substrate, locates services and performs the installation. Do not leave these tasks hidden inside a broad delivery line.
If the wall condition differs from the approved information, pause the affected fixing decision and obtain a revised method from the responsible parties. Avoid substituting a fixing by appearance alone. The selected catalogue rows provide no substrate or fixing specification to use as a default.
Retain the as-installed evidence
Record the installed position, relevant fixing reference and any approved variation before the details are concealed. Keep the supplier instructions and completion evidence in the facilities handover. Actual sensitive building information should remain in the buyer’s controlled records.
When the cabinet is moved or the wall changes later, review the original method rather than assuming it transfers to a new location. Include removal and refixing responsibilities in that future work scope. The furniture reference identifies the product, while the installation record identifies how it was accepted at the site.
Questions before ordering
Can the fixing be selected from cabinet height alone?
Use the actual cabinet, contents, wall information and supplier method for project review.
Does a furniture delivery line include wall preparation?
Confirm the scope and responsible parties explicitly.
Can an installed cabinet use the same fixing at a new wall?
Have the new wall condition and method reviewed before refixing.
What to include in the quotation request
- Confirmed wall information and installation location
- Supplier support or restraint proposal
- Hardware and site-work responsibilities
- As-installed method and approved variation record
Catalogue basis and confirmation
The reference and dimension examples come from the 2026 Yiwan English catalogue, Huanying. They support the purchasing comparison above. The selected components, materials and any required performance are confirmed through the supplier drawing and written order specification. Catalogue imagery is a design reference, not evidence of completed GulfForma projects.