A cabinet beside an office doorway needs more than a closed footprint check. XTB02-2012, XTB03-1012 and XTB04-0808 have different widths and heights with a listed 400 mm depth. The door, cabinet fronts, switches and a person using them can occupy space outside that closed rectangle.
Catalogue examples and dimensions
| Catalogue range | Catalogue reference | Listed dimensions (mm) |
|---|---|---|
| Xingtu | XTB02-2012 | 2000 × 400 × 1200 |
| Xingtu | XTB03-1012 | 1000W × 400D × 1200H |
| Xingtu | XTB04-0808 | 800 × 400 × 800 |
Overlay both sets of opening movements
Draw the room door with its actual opening direction and hardware, then add the supplier-confirmed cabinet door and drawer movements. Identify any point where the two can meet or where one prevents the other from opening. A generic cabinet symbol does not show those interactions.
Mark the location from which a person operates the cabinet. Check that using storage does not force that person into the doorway’s movement. Have the project team set any required circulation or access criteria rather than applying an arbitrary clearance to every room.
Keep controls and service points reachable
Show switches, outlets and other controls on an elevation beside the cabinet. XTB04 is listed at 800 mm high, while the XTB02 and XTB03 entries are 1200 mm high. Compare each against the actual control location, not a presumed standard mounting height.
Include handle projections and the route of plugs or leads where relevant. A cabinet that stops below a switch can still obstruct its operation or maintenance. If relocation is proposed, identify the responsible trade and approval before the furniture position is released.
Record the accepted stop and position details
Agree how the room door and cabinet openings are controlled in the final arrangement, where such details are needed. Keep those items identified as building hardware or furniture components with clear supply responsibilities. Do not infer stops or restrictors from the catalogue.
At installation, check the actual movements and control access against the accepted drawings. Record any change caused by a different door handle or cabinet front. Keep the final location in the handover so a later furniture move does not recreate the original conflict.
Questions before ordering
Does a closed 400 mm-deep cabinet prove doorway clearance?
Check the room door, cabinet openings, projections and user positions in use.
Can a lower cabinet automatically fit below a switch?
Compare the actual switch position and required access with the selected cabinet.
Are door stops or restrictors included?
Confirm the required hardware and its supplier separately.
What to include in the quotation request
- Room-door and cabinet movement overlay
- Switch and service-point elevation
- Accepted position and hardware scope
- Installed opening and control-access check
Catalogue basis and confirmation
The reference and dimension examples come from the 2026 Yiwan English catalogue, Xingtu. They support the purchasing comparison above. The selected components, materials and any required performance are confirmed through the supplier drawing and written order specification. Catalogue imagery is a design reference, not evidence of completed GulfForma projects.