Place the SRC02 support layout over the raised-floor drawing before approving a workstation location. SRC02-A and B are listed at 1500 × 2000 × 1050 mm, with and without steel legs respectively. That envelope does not locate individual support feet or establish the floor’s suitability for the installed furniture and equipment.
Catalogue examples and dimensions
| Catalogue range | Catalogue reference | Listed dimensions (mm) |
|---|---|---|
| Senrui | SRC02-A; (With steel legs) | 1500 × 2000 × 1050 |
| Senrui | SRC02-B; (Without steel legs) | 1500 × 2000 × 1050 |
Obtain the floor and furniture information together
Ask for the workstation support positions and the actual floor panel grid, service boxes and permitted access zones. Mark each support on the coordinated drawing. A large furniture rectangle can hide a foot on an opening or a panel that needs regular removal.
Have the responsible floor and project teams review the proposed loads and support arrangement using the relevant supplier information. Do not derive a structural acceptance from the catalogue’s overall dimensions. Keep any required floor-system confirmation with the installation approval.
Preserve access to the services below
Show which panels and box lids need to open after the workstations are installed. Test the intended access sequence with cabinets, screens and cables in their normal positions. If maintenance requires moving furniture, identify how that will be done and who is responsible.
Confirm the route from the floor service to the workstation’s cable entry. The route should not rely on trapping a cable under a removable panel or on an unapproved modification. The B version’s without-steel-legs wording does not explain its support or service relationship.
Agree any fixing before installation
If a fixing to the floor or another building element is proposed, obtain the method and approval from the relevant suppliers and project team before work begins. Do not assume that a raised panel can be drilled or used as an anchor merely because it lies under the desk.
At handover, keep an as-installed plan showing supports, floor access and service routes. Record any location that differs from the approved coordination drawing. That information helps future furniture moves avoid repeating assumptions about concealed services or the floor construction.
Questions before ordering
Can floor loading be assessed from the 1500 × 2000 mm envelope?
No. Obtain the actual support and equipment information for review by the responsible floor and project teams.
Does SRC02-B avoid the floor-support question?
Its support arrangement still needs confirmation. The model description is not a floor acceptance.
Can floor panels be drilled during installation?
Approve the specific fixing method and its compatibility with the floor system before doing the work.
What to include in the quotation request
- Furniture support and raised-floor overlay
- Supplier load information and project review
- Post-installation service-access sequence
- Approved fixing method and as-installed record
Catalogue basis and confirmation
The reference and dimension examples come from the 2026 Yiwan English catalogue, Senrui. They support the purchasing comparison above. The selected components, materials and any required performance are confirmed through the supplier drawing and written order specification. Catalogue imagery is a design reference, not evidence of completed GulfForma projects.