Schedule each parallel LJC01 run as its own assembly. The catalogue distinguishes LJC01-A with steel frame from LJC01-B extension, while listing the same 1200 × 1260 × 1030 mm envelope for both. The number of rooms and breaks in a layout matters as much as the total quantity of repeated units.
Catalogue dimensions
| Catalogue reference | Listed L × W × H (mm) |
|---|---|
| LJC01-A(With steel frame) | 1200 × 1260 × 1030 |
| LJC01-B(Extension) | 1200 × 1260 × 1030 |
Give every run a location and an assembly boundary
Assign identifiers such as Run A and Run B on the floor plan and mark each start and finish. A doorway, column or cross aisle may divide what looks like one row of desks into independently supported furniture. Submit those interruptions to the supplier before asking for the starter-to-extension breakdown.
A quotation for one continuous run should not be carried over unchanged to two shorter parallel runs. Request an assembly-specific list showing frames, shared junctions and terminal components. Do not derive the number of steel frames from a photograph or from a per-position rate.
Review the 1260 mm envelope against both occupied sides
Use the 1260 mm catalogue dimension when placing the assembly, then draw the actual chairs and their occupied and withdrawn positions. Confirm the worktop depth and screen position from a section; the overall width alone does not establish equal usable depth on both sides.
Keep the route between parallel runs distinct from the area occupied by chairs. Ask the project designer to confirm the circulation required for the location. A furniture drawing can identify conflicts but does not establish building-code compliance.
Allocate service access to the run that uses it
Show floor boxes and intended cable entry for each run. Obtain the location of any service panel or cable tray and check that it remains accessible after adjacent furniture is installed. If a socket option is requested, specify its count, outlet type and connection scope in writing rather than treating the catalogue furniture envelope as a complete power specification.
Questions before ordering
Can two parallel runs share one starter?
Only an approved support drawing can establish that. Keep the runs separate in the enquiry and request a frame schedule for each.
Is 1030 mm the desk working height?
It is the listed assembly height. Request a section identifying the worktop and any screen above it.
How do I compare quotations for the same layout?
Use the same run identifiers and require a component breakdown, end conditions and service inclusions against each run.
What to include in the quotation request
- Labelled parallel-run floor plan
- Frames, shared junctions and terminal components per run
- Chair positions and project circulation review
- Power option specification and service-panel access
Catalogue basis and confirmation
The model and dimension table is based on the 2026 Yiwan English catalogue, Ruijie. Confirm the selected configuration on the supplier drawing and written specification. Catalogue illustrations describe product designs and do not establish completed GulfForma projects.