The selected Xuying storage combinations are 2350, 2750 or 3150 mm wide, each 400 mm deep and 2160 mm high. For every width, the catalogue lists a combination using XYB01-0821 L and another using XYB02-0821 R. Equal overall dimensions therefore need separate component and elevation references.
Catalogue dimensions
| Catalogue reference | Listed dimensions (mm) |
|---|---|
| XYB01-0821 L XYB03-1621 | 2350 × 400 × 2160 |
| XYB01-0821 L XYB04-2021 | 2750 × 400 × 2160 |
| XYB01-0821 L XYB05-2421 | 3150 × 400 × 2160 |
| XYB02-0821 R XYB03-1621 | 2350 × 400 × 2160 |
| XYB02-0821 R XYB04-2021 | 2750 × 400 × 2160 |
| XYB02-0821 R XYB05-2421 | 3150 × 400 × 2160 |
Choose the end arrangement from the wall elevation
Draw the wall as viewed from the room and label the doorway, adjacent corner and nearby services. Place the L or R end module on that elevation using the supplier-confirmed orientation. A floor plan showing only a rectangle cannot communicate the position of an asymmetric end.
The listed combinations pair the handed end with XYB03-1621, XYB04-2021 or XYB05-2421. Retain the complete pair on the quotation line. Ordering only the total width would leave the end module unspecified and could produce the opposite arrangement in an otherwise matching envelope.
Use the combined catalogue dimensions for the fit check
Use 2350, 2750 and 3150 mm as the listed combined widths. Do not reconstruct a width from numbers within the component codes, because those numbers do not establish an installed joint or finished overall dimension. Request a drawing that locates the joints and any required end clearance.
Survey the wall at floor level and at the full 2160 mm height. A column, ceiling feature or wall service can affect the upper part even if the footprint fits. Confirm the access needed above and beside the assembly for installation; catalogue height does not include an assumed lifting allowance.
Align fixing, services and labels with the selected hand
Ask for the installation and fixing requirements for the actual assembly and wall construction. Confirm whether the proposed unit contains any lighting or electrical equipment, and itemise it if supplied. A catalogue illustration cannot establish the electrical scope of every listed combination.
Label the handed module and its partner by room and elevation reference. Before closing joints or fitting finishes, compare the first assembly with the accepted drawing. This makes it easier to detect a reversed end or mixed components while the installation can still be corrected.
Questions before ordering
Do equal 2750 mm widths mean the L and R combinations are identical?
They have different handed end references. Keep the selected component pair and orientation on the order.
Can component code numbers be added to obtain the overall width?
Use the catalogue combined width and the approved assembly drawing. Code numbers are not a joint-detail calculation.
Is a 2160 mm wall opening enough for installation?
Confirm the assembly method and access allowance as well as the finished height before approving the space.
What to include in the quotation request
- Room-facing wall elevation with handed end selected
- Complete component pair for each combined width
- Measured wall and installation-access information
- Fixing, service and carton-label requirements
Catalogue basis and confirmation
The model and dimension table is based on the 2026 Yiwan English catalogue, Xuying. Confirm the selected configuration on the supplier drawing and written specification. Catalogue illustrations describe product designs and do not establish completed GulfForma projects.