Place the actual 1550 × 1200 mm XTC03 envelope on the room plan before locating floor services. XTC03-A is listed with steel legs and XTC03-B without steel legs; both have an overall height of 1030 mm. A standard 1500 mm planning block would shorten each catalogue envelope by 50 mm and can conceal a service alignment problem.
Catalogue dimensions
| Catalogue reference | Listed dimensions (mm) |
|---|---|
| XTC03-A; With steel legs | 1550 × 1200 × 1030 |
| XTC03-B; Without steel legs | 1550 × 1200 × 1030 |
Choose a setting-out datum for each assembly
Identify a fixed survey point, such as a finished column face, and dimension the first complete assembly from it. Mark which edge of the 1550 mm envelope faces the principal aisle. Rotating the block changes the relationship between its 1550 and 1200 mm sides and the room services.
If a preliminary plan puts two complete 1550 mm envelopes end to end with no overlap, their arithmetic length is 3100 mm. This is a geometric illustration, not an approved combined assembly. Obtain the manufacturer connection detail before using a repeated pitch or subtracting shared parts.
Overlay floor boxes and the support arrangement
Show floor-box lids, plug access and the intended cable entry on the furniture plan. Ask for the locations of legs, underframe members and any cable tray rather than positioning a floor box from the centre of a catalogue photograph. An accessible lid on an empty floor may become obstructed by a support or storage component.
Keep XTC03-A and XTC03-B on separate lines. The without-steel-legs description does not explain what supports the selected B position, and it is not a statement that every other frame component is absent. Tie the quoted parts to the approved arrangement.
Resolve adjustments before the floor work is fixed
Compare the furniture setting-out drawing with the electrical drawing before either is released. Record whether a change will be made to the furniture position, service position or connection route, and identify the party approving it. Moving furniture to reach a socket can reduce a passage or alter chair movement elsewhere.
For an occupied refurbishment, include the order of disconnection, furniture movement and reconnection in the installation scope. Confirm worktop height and cable access in a section; 1030 mm is the catalogue overall height.
Questions before ordering
Can a 1500 mm standard block stand for XTC03?
Use 1550 mm for the listed first dimension. A smaller block can give a misleading fit against columns and services.
Does XTC03-B mean a freestanding desk with no legs?
The row says without steel legs. The selected support and connection arrangement needs supplier confirmation.
Can the floor box sit under the middle of the assembly?
Only after checking the lid, connector and maintenance access against the actual underframe and furniture components.
What to include in the quotation request
- Furniture datum and orientation on a measured plan
- Floor-box positions and opening directions
- Separate A/B support and accessory schedule
- Approved cable entry detail and drawing revision
Catalogue basis and confirmation
The model and dimension table is based on the 2026 Yiwan English catalogue, Xingtu. Confirm the selected configuration on the supplier drawing and written specification. Catalogue illustrations describe product designs and do not establish completed GulfForma projects.